Solenoid valves use coil-driven plungers to switch gas or liquid flow. 2/2, 3/2, 5/2 configurations. Festo (pneumatic), SMC (full range), Parker, Bürkert (fluid) and ASCO lead.

Solenoid Valve
Solenoid Valve
Solenoid valves switch via coil-driven plunger — controlling gas and liquid flow. Festo, SMC, Parker and Bürkert lead...
Solenoid valves switch via coil-driven plunger — controlling gas and liquid flow. Festo, SMC, Parker and Bürkert lead the German market across 2/2, 3/2, 5/2 configurations.
News
No news for this tag
FAQ
Q 2/2 vs 5/2?
A
First digit = ports, second = positions. 2/2: 2 ports, 2 positions (on/off). 5/2: 5 ports, 2 positions (double-acting cylinder). Pneumatic → 5/2; water/gas on-off → 2/2.
Q Direct-acting vs pilot?
A
Direct: low flow, low ΔP, fast (2-10 ms), bidirectional. Pilot: high flow, requires minimum ΔP (0.05-0.5 bar), slower (30-100 ms), unidirectional.
Q Fluid valve materials?
A
Bürkert 316L, Hastelloy, PTFE-lined. Strong acid/alkali and seawater → PTFE-lined with titanium poppet. Pure/pharma water → 316L + EPDM seals.